How to integrate LASE with a remote Control List
After installation, LogAnalyzer SE can be configured to utilize a remote Control List, which is similar to the Integrated installation mode option available during installation. In order to configure the LogAnalyzer SE server to integrate with a remote Control List, the below steps can be taken:
- Ensure that the target/destination server (Server that LogAnalyzer SE will integrate with) is configured to allow communication from the client server. See Configure Static RPC Port and Enable RPC Access in TMG/ISA Server.
- Configure the new Control List Server in the LogAnalyzer SE Settings Database (‘LAEE_Settings’ by default):
- On the SQL Server that contains the LogAnalyzer SE databases, run the following query:
NOTE: The default database names will be used in the below queries. Target_Server_Name and Client_Server_Name should be replaced with the correct names:
- On the SQL Server that contains the LogAnalyzer SE databases, run the following query:
UPDATE LAEE_Settings.dbo.AppSettings SET CategoryServerName = 'Target_Server_Name' WHERE CategoryServerName = 'Client_Server_Name'
- Restart the LA7Main service (along with dependent services).
- Restart the LA7Main service (along with dependent services).
Note: In order to apply the categorization changes to all currently loaded data, the log data must be ‘Completely’ re-categorized.